Seri SP - UL 1449 5th Ed Tipe 1CA DIN-rail SPD kanggo AC Power Supply
- Tipe 1ca SPD sing diakoni UL (ANSI/UL 1449 5th lan CSA-C22.2)
- Kapasitas surge 50kA 8/20 μs
- MCOV: 150-690Vac
- SCCR: 200kA - dites tanpa CB eksternal utawa sekring
- Tingkat proteksi tegangan rendah
- Konfigurasi pemasangan DIN-rel
- Indikasi kegagalan degradasi lan kontak sinyal remot opsional
- Modul pluggable kanggo panggantos gampang
- Desain disconnector termal paten global kanthi piranti pemadam busur, aman & dilindhungi dhewe, tanggap termal cepet lan fungsi potongan sirkuit sing sampurna
- SPD seri SP iki uga dites kanggo IEC61643-11, KEMA certified.
Napa Tipe 1 CA tinimbang Tipe 4 CA?
Ana sawetara SPD sing diakoni UL (Surge Protective Devices) ing pasar. Nanging elinga manawa akeh sing kalebu Type 4 CA (Component Assembly) nalika Prosurge's SPD yaiku Type 1 CA. Kanggo non-prosessional, kabeh UL recgonized karo tandha UL padha. Nanging ana bedane gedhe antarane Tipe 4 CA lan Tipe 1 CA SPDs.
Tipe 4 Component Assembly SPD (Component Recognized) –– Komponen iki
rakitan minangka rakitan SPD sing ora lengkap, sing biasane dipasang ing
produk panggunaan pungkasan sing kadhaptar anggere kabeh syarat sing bisa ditampa. Iki Tipe 4
rakitan komponen ora lengkap minangka SPD, mbutuhake evaluasi luwih lan ora
diijini dipasang ing lapangan minangka SPD mandiri. Asring, piranti kasebut mbutuhake
pangayoman overcurrent tambahan.
Tipe 4 CA SPD ora dikirim menyang tes safety kaya Intermediate Current Test lan Short Circuit Current Rating (SCCR) Test lan mulane kudu nggarap piranti proteksi safety ekstra.
Tipe 1, 2, 3 Component Assembly SPDs (Componen Recognized) - Iki minangka SPD Komponen sing Diakoni sing dievaluasi kanggo digunakake ing aplikasi SPD Tipe 1, 2 utawa 3. SPD komponen kasebut kudu ngliwati kabeh tes kegagalan safety listrik sing padha karo SPD Tipe 1, 2 utawa 3 sing kadhaptar. SPD Komponen sing Diakoni Tipe 1, 2 utawa 3 iki ora kudu bingung karo ANSI / UL 1449-2006 Tipe 4 Component Assemblies lan komponen SPD diskrit Tipe 5 sing mbutuhake komponen tambahan (bisa uga disconnectors safety), desain lan tes supaya bisa digunakake minangka piranti protèktif mundhak lengkap.
Prosurge Type 1 CA SPD pass 200kA SCCR (Short Circuit Current Rating) test kang watesan ndhuwur ing UL lab lan kanthi mangkono nggantosi standar paling dhuwur ing safety SPD.
Pilihan Model kanggo Piranti Proteksi Surge UL DIN-rel
Cagak siji
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |
Tipe 1 ca | Tipe 2 ca | |||||||
SP150-S | SP150C-S | 1 | 50 | 20 | 120 | 150 | 0.7 | 200 |
SP180-S | SP180C-S | 1 | 50 | 20 | 127 | 180 | 1 | 200 |
SP275A-S | SP275AC-S | 1 | 50 | 20 | 240 | 275 | 1 | 200 |
SP320-S | SP320C-S | 1 | 50 | 20 | 277 | 320 | 1.2 | 200 |
SP385-S | SP385C-S | 1 | 50 | 20 | 277 | 385 | 1.5 | 200 |
SP420-S | SP420C-S | 1 | 50 | 20 | 347 | 420 | 1.5 | 200 |
SP550-S | SP550C-S | 1 | 50 | 20 | 480 | 550 | 1.8 | 200 |
SP690-S | SP690C-S | 1 | 40 | 20 | 600 | 690 | 2.5 | 200 |
SP150T-S | SP150TC-S | 1 | 50 | 20 | Neutral | - | - | 200 |
SP255T-S | SP255TC-S | 1 | 50 | 20 | Neutral | - | - | 200 |
Fase Tunggal Dua Kawat + Sistem Ground
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP150 / 2P-S | SP150C / 2P-S | 2 | 50 | 20 | 120V | - | 150 | 150 | - | 0.7 | 0.7 | 200 |
SP150 / PN-S * | SP150C / PN-S * | 2 | 50 | 20 | 120V | 150 | - | 150 * | 0.7 | - | 0.9 | 200 |
SP180 / 2P-S | SP180C / 2P-S | 2 | 50 | 20 | 127V | - | 180 | 180 | - | 1.0 | 1.0 | 200 |
SP180 / PN-S * | SP180C / PN-S * | 2 | 50 | 20 | 127V | 180 | - | 150 * | 1.0 | - | 0.9 | 200 |
SP275A / 2P-S | SP275AC / 2P-S | 2 | 50 | 20 | 230V | - | 275 | 275 | - | 1.0 | 1.0 | 200 |
SP275A / PN-S * | SP275AC / PN-S * | 2 | 50 | 20 | 230V | 275 | - | 255 * | 1.0 | - | 0.9 | 200 |
SP320 / 2P-S | SP320C / 2P-S | 2 | 50 | 20 | 240V | - | 320 | 320 | - | 1.2 | 1.2 | 200 |
SP320 / PN-S * | SP320C / PN-S * | 2 | 50 | 20 | 240V | 320 | - | 255 * | 1.2 | - | 0.9 | 200 |
SP385 / 2P-S | SP385C / 2P-S | 2 | 50 | 20 | 277V | - | 385 | 385 | - | 1.5 | 1.5 | 200 |
SP385 / PN-S * | SP385C / PN-S * | 2 | 50 | 20 | 277V | 385 | - | 255 * | 1.5 | - | 0.9 | 200 |
SP420 / 2P-S | SP420C / 2P-S | 2 | 50 | 20 | 347V | - | 420 | 420 | - | 1.5 | 1.5 | 200 |
SP420 / PN-S * | SP420C / PN-S * | 2 | 50 | 20 | 347V | 420 | - | 255 * | 1.5 | - | 0.9 | 200 |
*PN: Modul GDT kanggo kutub N-PE
Split-phase Two-wire + Sistem Ground
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP150/2SPG-S | SP150C/2SPG-S | 2 | 50 | 20 | 120 / 240V | - | 150 | - | - | 0.7 | - | 200 |
SP180/2SPG-S | SP180C/2SPG-S | 2 | 50 | 20 | 120 / 240V | - | 180 | - | - | 1 | - | 200 |
SP320/2SPG-S | SP320C/2SPG-S | 2 | 50 | 20 | 240 / 480V | - | 320 | - | - | 1.2 | - | 200 |
∗ Model iki utamane digunakake kanggo aplikasi fase pamisah kanggo proteksi LG
Split-phase Tiga-kawat
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP150/2SPN-S | SP150C/2SPN-S | 2 | 50 | 20 | 120 / 240V | 150 | - | - | 0.7 | - | - | 200 |
SP180/2SPN-S | SP180C/2SPN-S | 2 | 50 | 20 | 120 / 240V | 180 | - | - | 1 | - | - | 200 |
SP320/2SPN-S | SP320C/2SPN-S | 2 | 50 | 20 | 240 / 480V | 320 | - | - | 1.2 | - | - | 200 |
* Model iki utamané digunakake kanggo pamisah phase aplikasi telung kabel.
Sistem tiga Ground Split-phase
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP150/3SP-S | SP150C/3SP-S | 3 | 50 | 20 | 120 / 240V | 150 | - | 150 | 0.7 | - | 0.7 | 200 |
SP180/3SP-S | SP180C/3SP-S | 3 | 50 | 20 | 120 / 240V | 180 | - | 180 | 1.0 | - | 1.0 | 200 |
SP320/3SP-S | SP320C/3SP-S | 3 | 50 | 20 | 240 / 480V | 320 | - | 320 | 1.2 | - | 1.2 | 200 |
* Model iki utamane digunakake kanggo aplikasi phase split kanggo mode proteksi L1 nganti G, L2-G lan N to G.
Telung fase WYE Telung kabel + Sistem Ground
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP150 / 3P-S | SP150C / 3P-S | 3 | 50 | 20 | 208Y/120V | - | 150 | - | - | 0.7 | - | 200 |
SP180 / 3P-S | SP180C / 3P-S | 3 | 50 | 20 | 220Y/127V | - | 180 | - | - | 1.0 | - | 200 |
SP275A / 3P-S | SP275AC / 3P-S | 3 | 50 | 20 | 400Y/230V | - | 275 | - | - | 1.0 | - | 200 |
SP320 / 3P-S | SP320C / 3P-S | 3 | 50 | 20 | 415Y/240V | - | 320 | - | - | 1.2 | - | 200 |
SP385 / 3P-S | SP385C / 3P-S | 3 | 50 | 20 | 480Y/277V | - | 385 | - | - | 1.5 | - | 200 |
SP420 / 3P-S | SP420C / 3P-S | 3 | 50 | 20 | 600Y/347V | - | 420 | - | - | 1.5 | - | 200 |
SP550 / 3P-S | SP550C / 3P-S | 3 | 50 | 20 | 600Y/347V | - | 550 | - | - | 1.8 | - | 200 |
Delta telung fase telung kabel + Ground System
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP320/3D-S | SP320C/3D-S | 3 | 50 | 20 | 240V | - | 320 | - | - | 1.2 | - | 200 |
SP550/3D-S | SP550C/3D-S | 50 | 20 | 480V | - | 550 | - | - | 1.8 | - | 200 | |
SP690/3D-S | SP690C/3D-S | 3 | 50 | 20 | 600V | - | 890 | - | - | 2.5 | - | 200 |
Telung fase WYE Papat kabel + Ground System
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP150 / 4P-S | SP150C / 4P-S | 4 | 50 | 20 | 208Y/120V | - | 150 | 150 | - | 0.7 | 0.7 | 200 |
SP150 / 3PN-S * | SP150C / 3PN-S * | 4 | 50 | 20 | 208Y/120V | 150 | - | 150 * | 0.7 | - | 0.9 | 200 |
SP180 / 4P-S | SP180C / 4P-S | 4 | 50 | 20 | 220Y/127V | - | 180 | 180 | - | 1.0 | 1.0 | 200 |
SP180 / 3PN-S * | SP180C / 3PN-S * | 4 | 50 | 20 | 220Y/127V | 180 | - | 150 * | 1.0 | - | 0.9 | 200 |
SP275A / 4P-S | SP275AC / 4P-S | 4 | 50 | 20 | 400Y/230V | - | 275 | 275 | - | 1.0 | 1.0 | 200 |
SP275A / 3PN-S * | SP275AC / 3PN-S * | 4 | 50 | 20 | 400Y/230V | 275 | - | 255 * | 1.0 | - | 0.9 | 200 |
SP320 / 4P-S | SP320C / 4P-S | 4 | 50 | 20 | 415Y/240V | - | 320 | 320 | - | 1.2 | 1.2 | 200 |
SP320 / 3PN-S * | SP320C / 3PN-S * | 4 | 50 | 20 | 415Y/240V | 320 | - | 255 * | 1.2 | - | 0.9 | 200 |
SP385 / 4P-S | SP385C / 4P-S | 4 | 50 | 20 | 480Y/277V | - | 385 | 385 | - | 1.5 | 1.5 | 200 |
SP385 / 3PN-S * | SP385C / 3PN-S * | 4 | 50 | 20 | 480Y/277V | 385 | - | 255 * | 1.5 | - | 0.9 | 200 |
SP420 / 4P-S | SP420C / 4P-S | 4 | 50 | 20 | 600Y/347V | - | 420 | 420 | - | 1.5 | 1.5 | 200 |
SP420 / 3PN-S * | SP420C / 3PN-S * | 4 | 50 | 20 | 600Y/347V | 420 | - | 255 * | 1.5 | - | 0.9 | 200 |
PN: Modul GDT kanggo kutub N-PE
Telu-phase Hi-leg Delta Four-kabel + Ground System
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |||||
Tipe 1 ca | Tipe 2 ca | LN | LG | NG | LN | LG | NG | |||||
SP240/3H-S | SP240C/3H-S | 4 | 50 | 20 | 240H/120V | 150 320(HL) | - | 150 | 0.7 1.2(HL) | - | 0.7 | 200 |
SP480/3H-S | SP480C/3H-S | 4 | 50 | 20 | 480H/240V | 320 550(HL) | - | 320 | 1.2 1.8(HL) | - | 1.2 | 200 |
Modul SPD Pluggable kanggo SP Series
Bagéan No |
Tipe Modul | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |
Tipe 1 ca | Tipe 2 ca | ||||||
MSP150 | MSP150C | MOV | 50 | 20 | 150 | 0.7 | 200 |
MSP180 | MSP180C | MOV | 50 | 20 | 180 | 1.0 | 200 |
MSP275A | MSP275AC | MOV | 50 | 20 | 275 | 1.0 | 200 |
MSP320 | MSP320C | MOV | 50 | 20 | 320 | 1.2 | 200 |
MSP385 | MSP385C | MOV | 50 | 20 | 385 | 1.5 | 200 |
MSP420 | MSP420C | MOV | 50 | 20 | 420 | 1.5 | 200 |
MSP550 | MSP550C | MOV | 50 | 20 | 550 | 1.8 | 200 |
MSP690 | MSP690C | MOV | 40 | 20 | 690 | 2.5 | 200 |
MSP150T | MSP150TC | GDT | 50 | 20 | 150 | 0.9 | 200 |
MSP255T | MSP255TC | GDT | 50 | 20 | 255 | 0.9 | 200 |
Max surge saiki 75kA SPD
Part No. | Pole | Maks. Arus Discharge, Imax (8/20μs) (kA) | Nominal Discharge Arus, Ing (8/20μs) (kA) | Tegangan Nominal (VAC) | Maks. Tegangan Operasi Terus-terusan, MCOV (VAC) | Voltage Protection Rating, VPR (kV) | Rating SCCR (kArms) | |
Tipe 1 ca | Tipe 2 ca | |||||||
SPD150-S | SPD150C-S | 1 | 75 | 20 | 120V | 150 | 0.7 | 200 |
SPD180-S | SPD180C-S | 1 | 75 | 20 | 127V | 180 | 1.0 | 200 |
SPD275A-S | SPD275AC-S | 1 | 75 | 20 | 230V | 275 | 1.0 | 200 |
SPD320-S | SPD320C-S | 1 | 75 | 20 | 277V | 320 | 1.2 | 200 |
Produk Produk Perlindungan Surge Surgege Surge
Klik kanggo njelajah piranti proteksi gelombang gedhe lan produk proteksi kilat liyane.
DIN-rail SPD kanggo AC Power Supply
SPD Panel kanggo AC Power Supply
Standar IEC
UL Standard
Produk Surge lan Lightning Protection liyane