Seri G50 LN: 50kA 10 / 350 μs
G100/xxxNPE: Maks 100kA 10/350 μs
50kA Kelas I / Tipe 1 Surge Protection Device (SPD) Fitur
- Non-pluggable T1 + 2 SPD karo teknologi Encapsulated Spark Gap (ESG) kanggo njamin linuwih ing lingkungan sing nggronjal lan lokasi eksposur dhuwur
- Kapasitas discharge dhuwur saiki nganti Iimp 50kA 10 / 350μs
- Indikasi penurunan & kontak sinyal jarak jauh opsional
- Tingkat proteksi tegangan rendah
- Miturut IEC / EN 61643-11, UL 1449 4th, IEEE C62.41, CSA C22.2
50kA Kelas I / Tipe 1 Surge Protection Device (SPD) Spec
model | G50 / 150-S | G50 / 175-S | G50 / 275-S | G50 / 320-S | G50 / 385-S | G50 / 420-S | |
Compliance | EN / IEC 61643-11 | ||||||
Kategori IEC / EN | Kelas I + II / T1 + 2 | ||||||
Maks. Tegangan Operasi Berterusan (AC) | Uc | 150V | 175V | 275V | 320V | 385V | 420V |
Teknologi | Teknologi ESG Disconnector Thermal | ||||||
Port / Mode Perlindungan | 1 / L-PE utawa LN utawa N-PE | ||||||
Lightning Impulse Current (10 / 350μs) | Iimp | 50kA | |||||
Nominal Discharge Current (8 / 20μs) | In | 50kA | |||||
Maks. Discharge Saiki (8 / 20μs) | Imax | 150kA | |||||
Tingkat Proteksi Tegangan | Up | ≤1.2kV | ≤1.2kV | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV |
TOV OverVoltage Sementara -Withstand Mode | Utov | 228V / 120min | 228V / 120min | 442V / 120min | 442V / 120min | 529V / 120min | 585V / 120min |
Sisa Saiki | IPE | Ora Ana | |||||
Tindakake Interrupt Rating Saiki | Yen aku | 25kA | |||||
Short-Circuit Rating Saiki kanggo IEC 61643-11 | Isc | 25kA | |||||
Response Wektu | tA | ≤100ns | |||||
Backup Fuse (mung dibutuhake yen durung kasedhiya ing induk) | 500A gL / gG | ||||||
lingkungan | Range Suhu: - 40ºC ~ + 85ºC; Asor: ≤95%; Ketinggian: ≤2000m | ||||||
Cross-Section of Connection Wire | Single-strand 35mm2; multi-untai 25mm2 | ||||||
soyo tambah | 35mm DIN-rail miturut EN 50022 / DIN46277-3 | ||||||
Bahan Lampiran | thermoplastic; gelar pemadam UL94 V-0 | ||||||
Degree Protection | IP20 | ||||||
Lebar Instalasi | Modul 2, DIN 43880 | ||||||
Indikator Gagal / Status | RED- Failure | ||||||
Jauh Kontak Weker | Ya | ||||||
Kelulusan, sertifikasi | CE | ||||||
Data tambahan kanggo Kontak Weker Cepet | |||||||
Tipe kontak remot remot | Formulir Isolasi C | ||||||
Kaping Switching Un / In | AC: 250V / 0.5A; DC: 250V / 0.1A; 125V / 0.2A; 75V / 0.5A | ||||||
Maks. Ukuran Nyambung Wire | Maks. 1.5mm2 (utawa # 16AWG) |
Kombinasi Piranti Proteksi Multi-Pole Surge
Part No. | Pole | Kombinasi | Sistem Daya | Maks. Operasi Tegangan Uc | Lightning Impulse Current (10 / 350μs) Iimp | Voltage Protection Level Up | Diagram |
G50 / 150-S / 2P | 2 | 2 x G50 / 150-S | Tahap tunggal 2W + G | 150Vac | 50kA | L / NG: 1.2kV | 4 |
G50 / 175-S / 2P | 2 | 2 x G50 / 175-S | Tahap tunggal 2W + G | 175Vac | 50kA | L / NG: 1.2kV | 4 |
G50 / 275-S / 2P | 2 | 2 x G50 / 275-S | Tahap tunggal 2W + G | 275Vac | 50kA | L / NG: 1.5kV | 4 |
G50 / 320-S / 2P | 2 | 2 x G50 / 320-S | Tahap tunggal 2W + G | 320Vac | 50kA | L / NG: 1.6kV | 4 |
G50 / 385-S / 2P | 2 | 2 x G50 / 385-S | Tahap tunggal 2W + G | 385Vac | 50kA | L / NG: 1.8kV | 4 |
G50 / 420-S / 2P | 2 | 2 x G50 / 420-S | Tahap tunggal 2W + G | 420Vac | 50kA | L / NG: 2.0kV | 4 |
G50 / 150-S / PN50 | 2 | G50 / 150-S + G50 / 255NPE | Tahap tunggal 2W + G | 150Vac | 50kA | LN: 1.2kV, N-PE: 1.5kV | 3 |
G50 / 175-S / PN50 | 2 | G50 / 175-S + G50 / 255NPE | Tahap tunggal 2W + G | 175Vac | 50kA | LN: 1.2kV, N-PE: 1.5kV | 3 |
G50 / 275-S / PN50 | 2 | G50 / 275-S + G50 / 255NPE | Tahap tunggal 2W + G | 275Vac | 50kA | LN: 1.5kV, N-PE: 1.5kV | 3 |
G50 / 320-S / PN50 | 2 | G50 / 320-S + G50 / 255NPE | Tahap tunggal 2W + G | 320Vac | 50kA | LN: 1.6kV, N-PE: 1.5kV | 3 |
G50 / 385-S / PN50 | 2 | G50 / 385-S + G50 / 255NPE | Tahap tunggal 2W + G | 385Vac | 50kA | LN: 1.8kV, N-PE: 1.5kV | 3 |
G50 / 420-S / PN50 | 2 | G50 / 420-S + G50 / 255NPE | Tahap tunggal 2W + G | 420Vac | 50kA | LN: 2.0kV, N-PE: 1.5kV | 3 |
G50 / 150-S / 3P | 3 | 3 x G50 / 150-S | Telung phase 3W + G | 150Vac | 50kA | LG: 1.2kV | 2 |
G50 / 175-S / 3P | 3 | 3 x G50 / 175-S | Telung phase 3W + G | 175Vac | 50kA | LG: 1.2kV | 2 |
G50 / 275-S / 3P | 3 | 3 x G50 / 275-S | Telung phase 3W + G | 275Vac | 50kA | LG: 1.5kV | 2 |
G50 / 320-S / 3P | 3 | 3 x G50 / 320-S | Telung phase 3W + G | 320Vac | 50kA | LG: 1.6kV | 2 |
G50 / 385-S / 3P | 3 | 3 x G50 / 385-S | Telung phase 3W + G | 385Vac | 50kA | LG: 1.8kV | 2 |
G50 / 420-S / 3P | 3 | 3 x G50 / 420-S | Telung phase 3W + G | 420Vac | 50kA | LG: 2.0kV | 2 |
G50 / 150-S / 3PN100 | 4 | 3 x G50 / 150-S + G100 / 255NPE | Telung phase 4W + G | 150Vac | 50kA / 100kA (NPE) | LN: 1.2kV, N-PE: 1.5kV | 1 |
G50 / 175-S / 3PN100 | 4 | 3 x G50 / 175-S + G100 / 255NPE | Telung phase 4W + G | 175Vac | 50kA / 100kA (NPE) | LN: 1.2kV, N-PE: 1.5kV | 1 |
G50 / 275-S / 3PN100 | 4 | 3 x G50 / 275-S + G100 / 255NPE | Telung phase 4W + G | 275Vac | 50kA / 100kA (NPE) | LN: 1.5kV, N-PE: 1.5kV | 1 |
G50 / 320-S / 3PN100 | 4 | 3 x G50 / 320-S + G100 / 255NPE | Telung phase 4W + G | 320Vac | 50kA / 100kA (NPE) | LN: 1.6kV, N-PE: 1.5kV | 1 |
G50 / 385-S / 3PN100 | 4 | 3 x G50 / 385-S + G100 / 255NPE | Telung phase 4W + G | 385Vac | 50kA / 100kA (NPE) | LN: 1.8kV, N-PE: 1.5kV | 1 |
G50 / 420-S / 3PN100 | 4 | 3 x G50 / 420-S + G100 / 255NPE | Telung phase 4W + G | 420Vac | 50kA / 100kA (NPE) | LN: 2.0kV, N-PE: 1.5kV | 1 |
Fitur Perlengkapan Surge N-PE Module Surge Protection (SPD)
- T1 + 2 SPD kanthi teknologi Encapsulated Spark Gap (ESG) kanggo njamin linuwih ing lingkungan sing nggronjal lan lokasi cahya sing dhuwur
- Kapasitas discharge arus dhuwur nganti Iimp 100kA 10 / 350
- Tingkat proteksi tegangan rendah
- Miturut IEC / EN 61643-11, UL 1449 4th, IEEE C62.41, CSA C22.2
Spesifikasi Perlindungan Surge Proteksi N-PE Module
model | G100 / 255NPE | G50 / 255NPE | G25 / 255NPE | |
Compliance | EN / IEC 61643-11 | |||
Kategori IEC / EN | Kelas I + II / T1 + 2 | |||
Maks. Tegangan Operasi Berterusan (AC) | Uc | 255V | ||
Teknologi | Teknologi ESG | |||
Port / Mode Perlindungan | 1 / N-PE | |||
Lightning Impulse Current (10 / 350μs) | Iimp | 100kA | 50kA | 25kA |
Nominal Discharge Current (8 / 20μs) | In | 100kA | 50kA | 25kA |
Maks. Discharge Saiki (8 / 20μs) | Imax | 200kA | 150kA | 100kA |
Level Proteksi Tegangan (1.2 / 50μs) | Up | ≤1.5kV | ||
TOV OverVoltage Sementara -Withstand Mode | Utov | 1200V / 200ms | ||
Sisa Saiki | IPE | Ora Ana | ||
Tindakake Interrupt Rating Saiki | Yen aku | 200A@255Vac | ||
Response Wektu | tA | ≤100ns | ||
lingkungan | Range Suhu: - 40ºC ~ + 85ºC; Asor: £ 95%; Dhuwur: £ 2000m | |||
Cross-Section of Connection Wire | Single-strand 35mm2; multi-untai 25mm2 | |||
soyo tambah | 35mm DIN-rail miturut EN 50022 / DIN46277-3 | |||
Bahan Lampiran | thermoplastic; gelar pemadam UL94 V-0 | |||
Degree Protection | IP20 | |||
Lebar Instalasi | Modul 2, DIN 43880 | |||
Kelulusan, sertifikasi | CE |
Produk Produk Perlindungan Surge Surgege Surge
Klik kanggo njelajah piranti proteksi gelombang gedhe lan produk proteksi kilat liyane.
DIN-rail SPD kanggo AC Power Supply
SPD Panel kanggo AC Power Supply
Standar IEC
UL Standard
Produk Surge lan Lightning Protection liyane
Email Prosurge lan Njaluk Balesan ing 2 Jam
waca carane competitive rega kita:)
Manggon langsung karo kita kanthi ngeklik tombol chatting ing pojok tengen ngisor
Isi Formulir Kontak lan Njaluk Balesan ing 2 Jam
Kanggo pasar Amérika Lor, hubungi
Kanggo pasar liyane, hubungi
+ 86 757 8632 7660