G50 Series LN: 50kA 10 / 350 μs
G100/xxxNPE: Max 100kA 10/350 μs
Tampok 50kA Class I / Type 1 Surge Protection Device (SPD) Tampok
- Non-pluggable T1 + 2 SPD na may Encapsulated Spark Gap (ESG) na teknolohiya upang magarantiya ang pagiging maaasahan sa masungit na kapaligiran at mataas na lokasyon ng pagkakalantad
- Mataas na kidlat kasalukuyang discharge kapasidad hanggang sa Iimp 50kA 10 / 350μs
- Pahiwatig ng pagkasira at opsyonal na contact ng malayuang signal
- Mababang antas ng proteksyon ng boltahe
- Sumunod sa IEC / EN 61643-11, UL 1449 4th, IEEE C62.41, CSA C22.2
50kA Class I / Type 1 Surge Protection Device (SPD) Spec
modelo | G50 / 150-S | G50 / 175-S | G50 / 275-S | G50 / 320-S | G50 / 385-S | G50 / 420-S | |
Pagsunod | EN / IEC 61643-11 | ||||||
Kategorya IEC / EN | Class I + II / T1 + 2 | ||||||
Max. Patuloy na Operating Voltage (AC) | Uc | 150V | 175V | 275V | 320V | 385V | 420V |
Teknolohiya | Teknolohiya ng ESG Thermal disconnector | ||||||
Port / Proteksyon Mode | 1 / L-PE o LN o N-PE | ||||||
Lightning Impulse Current (10 / 350μs) | Iimp | 50kA | |||||
Nominal Discharge Current (8 / 20μs) | In | 50kA | |||||
Max. Discharge Current (8 / 20μs) | Imax | 150kA | |||||
Antas ng Proteksyon ng Boltahe | Up | ≤1.2kV | ≤1.2kV | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV |
Temporary Overvoltage TOV -Upang Mode | Utov | 228V / 120min | 228V / 120min | 442V / 120min | 442V / 120min | 529V / 120min | 585V / 120min |
Tiraang Kasalukuyang | IPE | Hindi | |||||
Sundin ang Kasalukuyang Interrupt Rating | Ifi | 25kA | |||||
Kasalukuyang Rating ng Maikling-Circuit kada IEC 61643-11 | Isc | 25kA | |||||
Oras ng pagtugon | tA | ≤100ns | |||||
Backup Fuse (kinakailangan lamang kung hindi na ibinigay sa mains) | 500A gL / gG | ||||||
kapaligiran | Saklaw ng Temperatura: - 40ºC ~ + 85ºC; Humidity: ≤95%; Altitude: ≤2000m | ||||||
Cross-Seksyon ng Wire ng Koneksyon | Single-strand 35mm2; multi-strand 25mm2 | ||||||
Kabitan | 35mm Din-rail alinsunod sa EN 50022 / DIN46277-3 | ||||||
Material ng Enclosure | thermoplastic; extinguishing degree UL94 V-0 | ||||||
Degree of Protection | IP20 | ||||||
Lapad ng Pag-install | 2 modules, DIN 43880 | ||||||
Kabiguang Indikasyon / Katayuan | RED- Failure | ||||||
Remote Alarm Contact | Oo | ||||||
Mga pag-apruba, sertipikasyon | CE | ||||||
Karagdagang Data para sa Mga Contact ng Remote Alarm | |||||||
Uri ng Contact ng Remote Alarm | Isolated Form C | ||||||
Paglipat ng Kakayahan Un / In | AC: 250V / 0.5A; DC: 250V / 0.1A; 125V / 0.2A; 75V / 0.5A | ||||||
Max. Sukat ng Pagkonekta ng Wire | Max. 1.5mm2 (o # 16AWG) |
Kumbinasyon ng Proteksiyon ng Proteksiyon ng Multi-Pole Surge
Part No. | Poste | Kombinasyon | Power System | Max. Operating Voltage Uc | Lightning Impulse Current (10 / 350μs) Iimp | Antas ng Proteksyon ng Boltahe | dayagram |
G50 / 150-S / 2P | 2 | 2 x G50 / 150-S | Single phase 2W + G | 150Vac | 50kA | L / NG: 1.2kV | 4 |
G50 / 175-S / 2P | 2 | 2 x G50 / 175-S | Single phase 2W + G | 175Vac | 50kA | L / NG: 1.2kV | 4 |
G50 / 275-S / 2P | 2 | 2 x G50 / 275-S | Single phase 2W + G | 275Vac | 50kA | L / NG: 1.5kV | 4 |
G50 / 320-S / 2P | 2 | 2 x G50 / 320-S | Single phase 2W + G | 320Vac | 50kA | L / NG: 1.6kV | 4 |
G50 / 385-S / 2P | 2 | 2 x G50 / 385-S | Single phase 2W + G | 385Vac | 50kA | L / NG: 1.8kV | 4 |
G50 / 420-S / 2P | 2 | 2 x G50 / 420-S | Single phase 2W + G | 420Vac | 50kA | L / NG: 2.0kV | 4 |
G50 / 150-S / PN50 | 2 | G50 / 150-S + G50 / 255NPE | Single phase 2W + G | 150Vac | 50kA | LN: 1.2kV, N-PE: 1.5kV | 3 |
G50 / 175-S / PN50 | 2 | G50 / 175-S + G50 / 255NPE | Single phase 2W + G | 175Vac | 50kA | LN: 1.2kV, N-PE: 1.5kV | 3 |
G50 / 275-S / PN50 | 2 | G50 / 275-S + G50 / 255NPE | Single phase 2W + G | 275Vac | 50kA | LN: 1.5kV, N-PE: 1.5kV | 3 |
G50 / 320-S / PN50 | 2 | G50 / 320-S + G50 / 255NPE | Single phase 2W + G | 320Vac | 50kA | LN: 1.6kV, N-PE: 1.5kV | 3 |
G50 / 385-S / PN50 | 2 | G50 / 385-S + G50 / 255NPE | Single phase 2W + G | 385Vac | 50kA | LN: 1.8kV, N-PE: 1.5kV | 3 |
G50 / 420-S / PN50 | 2 | G50 / 420-S + G50 / 255NPE | Single phase 2W + G | 420Vac | 50kA | LN: 2.0kV, N-PE: 1.5kV | 3 |
G50 / 150-S / 3P | 3 | 3 x G50 / 150-S | Tatlong yugto 3W + G | 150Vac | 50kA | LG: 1.2kV | 2 |
G50 / 175-S / 3P | 3 | 3 x G50 / 175-S | Tatlong yugto 3W + G | 175Vac | 50kA | LG: 1.2kV | 2 |
G50 / 275-S / 3P | 3 | 3 x G50 / 275-S | Tatlong yugto 3W + G | 275Vac | 50kA | LG: 1.5kV | 2 |
G50 / 320-S / 3P | 3 | 3 x G50 / 320-S | Tatlong yugto 3W + G | 320Vac | 50kA | LG: 1.6kV | 2 |
G50 / 385-S / 3P | 3 | 3 x G50 / 385-S | Tatlong yugto 3W + G | 385Vac | 50kA | LG: 1.8kV | 2 |
G50 / 420-S / 3P | 3 | 3 x G50 / 420-S | Tatlong yugto 3W + G | 420Vac | 50kA | LG: 2.0kV | 2 |
G50 / 150-S / 3PN100 | 4 | 3 x G50 / 150-S + G100 / 255NPE | Tatlong yugto 4W + G | 150Vac | 50kA / 100kA (NPE) | LN: 1.2kV, N-PE: 1.5kV | 1 |
G50 / 175-S / 3PN100 | 4 | 3 x G50 / 175-S + G100 / 255NPE | Tatlong yugto 4W + G | 175Vac | 50kA / 100kA (NPE) | LN: 1.2kV, N-PE: 1.5kV | 1 |
G50 / 275-S / 3PN100 | 4 | 3 x G50 / 275-S + G100 / 255NPE | Tatlong yugto 4W + G | 275Vac | 50kA / 100kA (NPE) | LN: 1.5kV, N-PE: 1.5kV | 1 |
G50 / 320-S / 3PN100 | 4 | 3 x G50 / 320-S + G100 / 255NPE | Tatlong yugto 4W + G | 320Vac | 50kA / 100kA (NPE) | LN: 1.6kV, N-PE: 1.5kV | 1 |
G50 / 385-S / 3PN100 | 4 | 3 x G50 / 385-S + G100 / 255NPE | Tatlong yugto 4W + G | 385Vac | 50kA / 100kA (NPE) | LN: 1.8kV, N-PE: 1.5kV | 1 |
G50 / 420-S / 3PN100 | 4 | 3 x G50 / 420-S + G100 / 255NPE | Tatlong yugto 4W + G | 420Vac | 50kA / 100kA (NPE) | LN: 2.0kV, N-PE: 1.5kV | 1 |
Tampok ng Proteksiyon ng Module Surge ng N-PE (SPD)
- T1 + 2 SPD na may Encapsulated Spark Gap (ESG) na teknolohiya upang magarantiya ang pagiging maaasahan sa masungit na kapaligiran at mataas na lokasyon ng pagkakalantad
- Mataas na kidlat kasalukuyang discharge kapasidad hanggang sa Iimp 100kA 10 / 350
- Mababang antas ng proteksyon ng boltahe
- Sumunod sa IEC / EN 61643-11, UL 1449 4th, IEEE C62.41, CSA C22.2
N-PE Module Surge Protection Device (SPD) Pagtutukoy
modelo | G100 / 255NPE | G50 / 255NPE | G25 / 255NPE | |
Pagsunod | EN / IEC 61643-11 | |||
Kategorya IEC / EN | Class I + II / T1 + 2 | |||
Max. Patuloy na Operating Voltage (AC) | Uc | 255V | ||
Teknolohiya | Teknolohiya ng ESG | |||
Port / Proteksyon Mode | 1 / N-PE | |||
Lightning Impulse Current (10 / 350μs) | Iimp | 100kA | 50kA | 25kA |
Nominal Discharge Current (8 / 20μs) | In | 100kA | 50kA | 25kA |
Max. Discharge Current (8 / 20μs) | Imax | 200kA | 150kA | 100kA |
Antas ng Proteksyon ng Boltahe (1.2 / 50μs) | Up | ≤1.5kV | ||
Temporary Overvoltage TOV -Upang Mode | Utov | 1200V / 200ms | ||
Tiraang Kasalukuyang | IPE | Hindi | ||
Sundin ang Kasalukuyang Interrupt Rating | Ifi | 200A@255Vac | ||
Oras ng pagtugon | tA | ≤100ns | ||
kapaligiran | Saklaw ng Temperatura: - 40ºC ~ + 85ºC; Humidity: £ 95%; Altitude: £ 2000m | |||
Cross-Seksyon ng Wire ng Koneksyon | Single-strand 35mm2; multi-strand 25mm2 | |||
Kabitan | 35mm Din-rail alinsunod sa EN 50022 / DIN46277-3 | |||
Material ng Enclosure | thermoplastic; extinguishing degree UL94 V-0 | |||
Degree of Protection | IP20 | |||
Lapad ng Pag-install | 2 modules, DIN 43880 | |||
Mga pag-apruba, sertipikasyon | CE |
Mga Produktong Proteksyon ng Produkto ng Prosurge Surge Pamilya
I-click upang galugarin ang aming malawak na proteksyon ng mga aparato at iba pang mga produkto ng proteksyon ng kidlat.
DIN-rail SPD para sa AC Power Supply
Panel SPD para sa AC Power Supply
IEC Standard
UL Standard
Iba pang Mga Produkto ng Proteksyon ng Surge at Lightning
Email Prosurge at Kumuha ng Sumagot sa 2 Oras
tingnan kung gaano mapagkumpitensya ang aming presyo ay:)
Live chat sa amin sa pamamagitan ng pag-click sa pindutan ng chat sa kanang sulok sa ibaba
Punan ang Contact Form at Kumuha ng Sumagot sa 2 Oras
Para sa North American market, mangyaring makipag-ugnay
Para sa iba pang mga merkado, mangyaring makipag-ugnay
+ 86 757 8632 7660