G50-reeks LN: 50kA 10 / 350 μs
G100/xxxNPE: Maksimum 100kA 10/350 μs
50kA Klas I / Type 1 Spanningsbeskermingsapparaat (SPD)
- Nie-pluggable T1 + 2 SPD met Encapsulated Spark Gap (ESG) tegnologie om betroubaarheid te verseker in 'n rowwe omgewing en hoë blootstelling plek
- Hoë weerligstroomafvoerkapasiteit tot Iimp 50kA 10 / 350μs
- Degradasie-aanduiding en opsionele kontak op afstand
- Lae spanning beskerming vlak
- Voldoen aan IEC / EN 61643-11, UL 1449 4th, IEEE C62.41, CSA C22.2
50kA Klas I / Type 1 Surge Protection Device (SPD) Spes
model | G50 / 150-S | G50 / 175-S | G50 / 275-S | G50 / 320-S | G50 / 385-S | G50 / 420-S | |
Compliance | EN / IEC 61643-11 | ||||||
Kategorie IEC / EN | Klas I + II / T1 + 2 | ||||||
Max. Deurlopende Bedryfspanning (AC) | Uc | 150V | 175V | 275V | 320V | 385V | 420V |
Tegnologie | ESG tegnologie Termiese ontkoppelaar | ||||||
Hawens / Beskermingsmodus | 1 / L-PE of LN of N-PE | ||||||
Weerlig-impulsstroom (10 / 350μs) | Iimp | 50kA | |||||
Nominale afvoerstroom (8 / 20μs) | In | 50kA | |||||
Max. Afvoerstroom (8 / 20μs) | Imax | 150kA | |||||
Spanningsbeskermingsvlak | Up | ≤1.2kV | ≤1.2kV | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV |
Tydelike oorspanning TOV -Withstand Modus | Utov | 228V / 120min | 228V / 120min | 442V / 120min | 442V / 120min | 529V / 120min | 585V / 120min |
Residuele stroom | IPE | Geen | |||||
Volg huidige onderbrekingsgradering | As ek | 25kA | |||||
Kortsluitstroom-aanslag per IEC 61643-11 | ISC | 25kA | |||||
Reaksie tyd | tA | ≤100ns | |||||
Backup Fuse (slegs benodig indien dit nie reeds in die hoofnet voorsien word nie) | 500A gL / gG | ||||||
omgewing | Temperatuurbereik: - 40ºC ~ + 85ºC; Humiditeit: ≤95%; Hoogte: ≤2000m | ||||||
Dwarsdeursnee van verbindingsdraad | Enkelstring 35mm2; multi-draad 25mm2 | ||||||
Montage | 35mm DIN-spoor volgens EN 50022 / DIN46277-3 | ||||||
Omhulsel Materiaal | termoplastiese; blusgraad UL94 V-0 | ||||||
Graad van beskerming | IP20 | ||||||
Installasie Breedte | 2 modules, DIN 43880 | ||||||
Versuimindikasie / Status | RED-Failure | ||||||
Remote Alarm Kontak | Ja | ||||||
Goedkeurings, sertifisering | CE | ||||||
Bykomende data vir eksterne alarmkontakte | |||||||
Remote Alarm Kontak Tipe | Geïsoleerde vorm C | ||||||
Skakel vermoë Un / In | AC: 250V / 0.5A; GS: 250V / 0.1A; 125V / 0.2A; 75V / 0.5A | ||||||
Max. Grootte van aansluitende draad | Maks. 1.5 mm2 (of # 16AWG) |
Multi Pole Surge Protection Device Combination
Deel No. | Pole | Kombinasie | Kragstelsel | Max. Bedryfspanning Uc | Weerlig Impulsstroom (10 / 350μs) Iimp | Voltage Protection Level Up | Diagram |
G50 / 150-S / 2P | 2 | 2 x G50 / 150-S | Enkelfase 2W + G | 150Vac | 50kA | L / NG: 1.2kV | 4 |
G50 / 175-S / 2P | 2 | 2 x G50 / 175-S | Enkelfase 2W + G | 175Vac | 50kA | L / NG: 1.2kV | 4 |
G50 / 275-S / 2P | 2 | 2 x G50 / 275-S | Enkelfase 2W + G | 275Vac | 50kA | L / NG: 1.5kV | 4 |
G50 / 320-S / 2P | 2 | 2 x G50 / 320-S | Enkelfase 2W + G | 320Vac | 50kA | L / NG: 1.6kV | 4 |
G50 / 385-S / 2P | 2 | 2 x G50 / 385-S | Enkelfase 2W + G | 385Vac | 50kA | L / NG: 1.8kV | 4 |
G50 / 420-S / 2P | 2 | 2 x G50 / 420-S | Enkelfase 2W + G | 420Vac | 50kA | L / NG: 2.0kV | 4 |
G50 / 150-S / PN50 | 2 | G50 / 150-S + G50 / 255NPE | Enkelfase 2W + G | 150Vac | 50kA | LN: 1.2kV, N-PE: 1.5kV | 3 |
G50 / 175-S / PN50 | 2 | G50 / 175-S + G50 / 255NPE | Enkelfase 2W + G | 175Vac | 50kA | LN: 1.2kV, N-PE: 1.5kV | 3 |
G50 / 275-S / PN50 | 2 | G50 / 275-S + G50 / 255NPE | Enkelfase 2W + G | 275Vac | 50kA | LN: 1.5kV, N-PE: 1.5kV | 3 |
G50 / 320-S / PN50 | 2 | G50 / 320-S + G50 / 255NPE | Enkelfase 2W + G | 320Vac | 50kA | LN: 1.6kV, N-PE: 1.5kV | 3 |
G50 / 385-S / PN50 | 2 | G50 / 385-S + G50 / 255NPE | Enkelfase 2W + G | 385Vac | 50kA | LN: 1.8kV, N-PE: 1.5kV | 3 |
G50 / 420-S / PN50 | 2 | G50 / 420-S + G50 / 255NPE | Enkelfase 2W + G | 420Vac | 50kA | LN: 2.0kV, N-PE: 1.5kV | 3 |
G50 / 150-S / 3P | 3 | 3 x G50 / 150-S | Drie fase 3W + G | 150Vac | 50kA | LG: 1.2kV | 2 |
G50 / 175-S / 3P | 3 | 3 x G50 / 175-S | Drie fase 3W + G | 175Vac | 50kA | LG: 1.2kV | 2 |
G50 / 275-S / 3P | 3 | 3 x G50 / 275-S | Drie fase 3W + G | 275Vac | 50kA | LG: 1.5kV | 2 |
G50 / 320-S / 3P | 3 | 3 x G50 / 320-S | Drie fase 3W + G | 320Vac | 50kA | LG: 1.6kV | 2 |
G50 / 385-S / 3P | 3 | 3 x G50 / 385-S | Drie fase 3W + G | 385Vac | 50kA | LG: 1.8kV | 2 |
G50 / 420-S / 3P | 3 | 3 x G50 / 420-S | Drie fase 3W + G | 420Vac | 50kA | LG: 2.0kV | 2 |
G50 / 150-S / 3PN100 | 4 | 3 x G50 / 150-S + G100 / 255NPE | Drie fase 4W + G | 150Vac | 50kA / 100kA (NPE) | LN: 1.2kV, N-PE: 1.5kV | 1 |
G50 / 175-S / 3PN100 | 4 | 3 x G50 / 175-S + G100 / 255NPE | Drie fase 4W + G | 175Vac | 50kA / 100kA (NPE) | LN: 1.2kV, N-PE: 1.5kV | 1 |
G50 / 275-S / 3PN100 | 4 | 3 x G50 / 275-S + G100 / 255NPE | Drie fase 4W + G | 275Vac | 50kA / 100kA (NPE) | LN: 1.5kV, N-PE: 1.5kV | 1 |
G50 / 320-S / 3PN100 | 4 | 3 x G50 / 320-S + G100 / 255NPE | Drie fase 4W + G | 320Vac | 50kA / 100kA (NPE) | LN: 1.6kV, N-PE: 1.5kV | 1 |
G50 / 385-S / 3PN100 | 4 | 3 x G50 / 385-S + G100 / 255NPE | Drie fase 4W + G | 385Vac | 50kA / 100kA (NPE) | LN: 1.8kV, N-PE: 1.5kV | 1 |
G50 / 420-S / 3PN100 | 4 | 3 x G50 / 420-S + G100 / 255NPE | Drie fase 4W + G | 420Vac | 50kA / 100kA (NPE) | LN: 2.0kV, N-PE: 1.5kV | 1 |
N-PE Module Surge Protection Device (SPD) funksies
- T1 + 2 SPD met Encapsulated Spark Gap (ESG) tegnologie om betroubaarheid te verseker in 'n rowwe omgewing en hoë blootstelling plek
- Hoë weerligstroomafvoerkapasiteit tot Iimp 100kA 10 / 350
- Lae spanning beskerming vlak
- Voldoen aan IEC / EN 61643-11, UL 1449 4th, IEEE C62.41, CSA C22.2
N-PE Module Surge Protection Device (SPD) Spesifikasies
model | G100 / 255NPE | G50 / 255NPE | G25 / 255NPE | |
Compliance | EN / IEC 61643-11 | |||
Kategorie IEC / EN | Klas I + II / T1 + 2 | |||
Max. Deurlopende Bedryfspanning (AC) | Uc | 255V | ||
Tegnologie | ESG tegnologie | |||
Hawens / Beskermingsmodus | 1 / N-PE | |||
Weerlig-impulsstroom (10 / 350μs) | Iimp | 100kA | 50kA | 25kA |
Nominale afvoerstroom (8 / 20μs) | In | 100kA | 50kA | 25kA |
Max. Afvoerstroom (8 / 20μs) | Imax | 200kA | 150kA | 100kA |
Spanningsbeskermingsvlak (1.2 / 50μs) | Up | ≤1.5kV | ||
Tydelike oorspanning TOV -Withstand Modus | Utov | 1200V / 200ms | ||
Residuele stroom | IPE | Geen | ||
Volg huidige onderbrekingsgradering | As ek | 200A@255Vac | ||
Reaksie tyd | tA | ≤100ns | ||
omgewing | Temperatuurbereik: - 40ºC ~ + 85ºC; Humiditeit: £ 95%; Hoogte: £ 2000 miljoen | |||
Dwarsdeursnee van verbindingsdraad | Enkelstring 35mm2; multi-draad 25mm2 | |||
Montage | 35mm DIN-spoor volgens EN 50022 / DIN46277-3 | |||
Omhulsel Materiaal | termoplastiese; blusgraad UL94 V-0 | |||
Graad van beskerming | IP20 | |||
Installasie Breedte | 2 modules, DIN 43880 | |||
Goedkeurings, sertifisering | CE |
Prosurge Surge Protection Apparaat Produkte Familie
Klik om ons uitgebreide skermbeskermings toestelle en ander weerligbeskermingsprodukte te ondersoek.
DIN-rail SPD vir AC Power Supply
Paneel SPD vir AC kragtoevoer
IEC Standard
UL Standaard
Ander Surge and Lightning Protection Products
E-posprobleem en kry antwoord in 2 Ure
sien hoe mededingend ons prys is:)
Live chat met ons deur te kliek op die klets knoppie in die onderste regterkantste hoek
Vul die kontakvorm in en kry antwoord in 2 ure
Vir Noord-Amerikaanse mark, kontak asb
Vir ander markte, kontak asb
+86 757 8632 7660