I-Class I+ Class II / Type 1+ Type 2 Surge Protection Device (SPD)

Prosurge’s Type 1 + Type 2 Amadivayisi Wokuvikelwa Okudlulele (SPDs) are designed to discharge high current surges without any destruction of the installation.

This surge protective device is characterized by its capacity to withstand impulse current with 10/350µs waveform which simulates direct impact coming from a natural lightning current.

Prosurge Type 1 + Type 2 (class I + Class II)  SPDs are placed at the entrance point of the installation, in the main distribution board for a global protection of this installation.

Prosurge also provides Class I + Class II, Type 1 + Type 2 SPD with different technology of spark gap technology, VT technology and MOV technology.

Class-1-2-Type-1-2-SPD_triggered-spark-gap-technology-Prosurge-258×212

Ubuchwepheshe be-MOV -12.5kA 10/350 – I-TUV iqinisekisiwe

Class-1-2-Type-1-2-SPD_triggered-spark-gap-technology-Prosurge-258×212

Ubuchwepheshe be-MOV – 25kA 10/350 – I-TUV iqinisekisiwe

Class-1-2-Type-1-2-SPD_triggered-spark-gap-technology-Prosurge-258×212

Class II / Type 2 (also tested to class I + Class II, T1 +T2) Surge Protection Device (SPD)

Prosurge Type 2 Amadivayisi Wokuvikelwa Okudlulele (SPDs) are also tested to Type 1 + Type 2 with impulse current 10/350µs.

It is designed to discharge high current surges without any destruction of the installation. This surge protective device is characterized by its capacity to withstand impulse current with 10/350µs waveform which simulates direct impact coming from a natural lightning current. Prosurge Type 2 SPD (also T1 + T2) SPDs are placed at the entrance point of the installation, in the main distribution board for a global protection of this installation.

Isilinganiselwa:

  • Uc range: 75Vac to 750Vac
  • Imax: 50kA 8/20
  • Iimp: 7.5kA 10/350
  • Various SPD configuration: 1+1, 2+0, 3+0, 3+1 SPD

I-Class II / Uhlobo lwe-2 Ukuvikelwa Kwesisindo (SPD)

Prosurge Class II/T2 surge protective device is designed for low-voltage power supply system protection against surges at the boundaries from lightning protection zone 1-2 and higher.

  • KEMA certified Class II/T2 SPD per IEC/EN 61643-11.
  • UL certified Type 1ca SPD per UL1449 5th edition (pass SCCR test 200kArms)
  • Ukukhishwa kwamanje kwamandla okukhishwa kwamandla kuze kufike ku-40kA 8 / 20μs
  • High reliability due to global patented thermally protected MOV with reliable arc-extinguish (TPAE) technology.
  • Imodi ene-plugable for replacement elula
  • Degradation indication and remote signal contact.
  • Comply with IEC/EN 61643-11, UL1449 5th, CSA C22.2 etc standards

Isigaba III / Uhlobo lwe-3 Surge Protection Device (SPD)

Prosurge T3 Surge Protection Device (SPD) is designed for low-voltage power supply system protection against surges at the boundaries from lightning protection zone 2-3 and higher.

Zizofakwa eduze ngangokunokwenzeka kusukela kusixhobo esibucayi sokuvikela. Kuvivinywe nge-generator engu-1,2 / 50 - 8/20 yenhlanganisela yamanje yama-wave, iqinisekisa inani lamandla wevolthi ephansi kakhulu.

  • Comply with IEC 61643-11 and UL1449 5th
  • I-design pluggable, ishintshwe kalula ngaphandle kwamathuluzi.
  • High Discharge Capacity with 8/20 us waveform, Imax 10kA to 25kA 8/20
  • Ukuthembeka okuphezulu ngenxa yedivayisi yokunqamula ukushisa
  • Isibonakaliso sesimo sokubukwa kanye noxhumano lwezignali ezikude olutholakala
  • Mono block type for single phase and three phase configuration are available

I-PCB Mounting SPD - Iyaxhumeka ngenkathi ifaka ngesokhethi yokunamathisela

The PCB mounting surge protective device is easy untegrated in PCB and close to sensitive electronic element inside device, to minimize the potential impact of lightning events. The PCB mounting SPD will help to significantly reduce the cost of substantial repair, replacement, system downtime and the loss of revenue.

I-Prosurge's PCB efaka i-SPD ye-SPD iwukwenza kahle usayizi kanye nokusebenza kahle kwesikhala, okuwukusebenza okuphezulu kodwa isisombululo sezindleko eziphansi embonini yamandla kagesi. Isebenzisa amandla aphezulu i-Metal Oxide Varistor (MOV), futhi yakhiwe ngokuvikela okushisayo okunelungelo lobunikazi kanye nobuchwepheshe bokucima i-arc obuqinisekisa ukunqanyulwa okuphephile kuyilapho kwenzeka i-voltage engalungile noma engavamile. Ama-SPD afaka i-Prosurge PCB athuthukise ngokujulile ukusebenza kokuphepha futhi afakazelwa njengamadivayisi ahle kakhulu angaphumeleli futhi azivikelayo ngenxa yobuchwepheshe obunelungelo lobunikazi.

  • Isilinganiselwa:
    • Ngohlelo lokusebenza lwe-AC: Max. I-voltage yokusebenza eqhubekayo (MCOV): 75~750Vac
    • Ngohlelo lokusebenza lwe-DC/PV: I-Max. I-Voltage DC evunyelwe (Vpvdc): 48-825Vdc
    • Umthamo wokuhlinza (8/20 μs): 50kA ~ 80kA
    • I-Ipulse current (10/350 μs): 7.5kA ~ 12.5kA
    • SCCR(UL1449 5th):up to 200kA – tested without external CB or fuse
    • Iscpv (IEC61643-31):1000A
  • I-UL eyaziwayo Yohlobo 1ca SPD (ANSI/UL1449 5th), Uhlobo 2ca SPD (CSA-C22.2)
  • I-TUV iqinisekiswe ngokwe-IEC 61643-31 ejwayelekile
  • Ukusabela okusheshayo okushisa nokusebenza okuphelele kwesinqamuleli se-circuit ngenxa yesakhiwo esikhethekile se-disconnector design nedivayisi yokucima i-arc
  • Uhlaka lokushisa olubanzi lokusebenza nokuthembeka okuphezulu
  • Umthamo wamanje wokuphakama okuphezulu nokuvuza okuphansi okwamanje
  • Oxhumana naye okude okusayinayo okubonisa ukukhombiswa kwephutha ngenkathi usebenzisa okunye kwe-PVD_Base

Imikhiqizo ye-Prosurge Surge Protection Device Imindeni

Chofoza ukuze uhlole amadivayisi ethu wokuvikelwa okunamandla kanye neminye imikhiqizo yokuvikela umbane.

Xhumana neProsurge bese uphendula kumahora ayi-2

bheka ukuthi ukuncintisana ngentengo yethu yilezi:)

Phila uxoxe nathi ngokuchofoza inkinobho yokuxoxa ekhoneni elingezansi elingakwesokudla

Gcwalisa ifomu lokuxhumana bese uthole impendulo kumahora we-2





Kumakethe yaseNyakatho Melika, sicela uthinte

+86 757 8632 7660

Kweminye imakethe, sicela uxhumane

+86 757 8632 7660