Kilasi I+ Kilasi II / Iru 1+ Iru 2 Ẹrọ Idaabobo Iṣẹ abẹ (SPD)

Prosurge’s Type 1 + Type 2 Awọn Ẹrọ Idaabobo Siri (SPDs) are designed to discharge high current surges without any destruction of the installation.

This surge protective device is characterized by its capacity to withstand impulse current with 10/350µs waveform which simulates direct impact coming from a natural lightning current.

Prosurge Type 1 + Type 2 (class I + Class II)  SPDs are placed at the entrance point of the installation, in the main distribution board for a global protection of this installation.

Prosurge also provides Class I + Class II, Type 1 + Type 2 SPD with different technology of spark gap technology, VT technology and MOV technology.

Class-1-2-Type-1-2-SPD_triggered-spark-gap-technology-Prosurge-258×212

MOV Technology -12.5kA 10/350 – TUV ifọwọsi

Class-1-2-Type-1-2-SPD_triggered-spark-gap-technology-Prosurge-258×212

MOV Technology – 25kA 10/350 – TUV ifọwọsi

Class-1-2-Type-1-2-SPD_triggered-spark-gap-technology-Prosurge-258×212

Class II / Type 2 (also tested to class I + Class II, T1 +T2) Surge Protection Device (SPD)

Prosurge Type 2 Awọn Ẹrọ Idaabobo Siri (SPDs) are also tested to Type 1 + Type 2 with impulse current 10/350µs.

It is designed to discharge high current surges without any destruction of the installation. This surge protective device is characterized by its capacity to withstand impulse current with 10/350µs waveform which simulates direct impact coming from a natural lightning current. Prosurge Type 2 SPD (also T1 + T2) SPDs are placed at the entrance point of the installation, in the main distribution board for a global protection of this installation.

Rating:

  • Uc range: 75Vac to 750Vac
  • Imax: 50kA 8/20
  • Iimp: 7.5kA 10/350
  • Various SPD configuration: 1+1, 2+0, 3+0, 3+1 SPD

Ipele II / Iru 2 Surge Protection Device (SPD)

Prosurge Class II/T2 surge protective device is designed for low-voltage power supply system protection against surges at the boundaries from lightning protection zone 1-2 and higher.

  • KEMA certified Class II/T2 SPD per IEC/EN 61643-11.
  • UL certified Type 1ca SPD per UL1449 5th edition (pass SCCR test 200kArms)
  • Imudani agbara fifun ti o ga julọ si 40kA 8 / 20μs
  • High reliability due to global patented thermally protected MOV with reliable arc-extinguish (TPAE) technology.
  • Eto apẹrẹ fun rirọpo rorun
  • Degradation indication and remote signal contact.
  • Comply with IEC/EN 61643-11, UL1449 5th, CSA C22.2 etc standards

Kilasi III / Iru Ẹrọ Idaabobo Iboju (SPD)

Prosurge T3 Surge Protection Device (SPD) is designed for low-voltage power supply system protection against surges at the boundaries from lightning protection zone 2-3 and higher.

Wọn yoo fi sori ẹrọ ni isunmọ bi o ti ṣee ṣe lati awọn ohun elo ifura lati daabobo. Idanwo pẹlu monomono igbi idapọ lọwọlọwọ 1,2 / 50 - 8/20, wọn ṣe idaniloju iye folti aabo ipele kekere pupọ.

  • Comply with IEC 61643-11 and UL1449 5th
  • Aṣa apẹrẹ, rọọrun rọpo laisi eyikeyi irinṣẹ.
  • High Discharge Capacity with 8/20 us waveform, Imax 10kA to 25kA 8/20
  • Gbẹkẹle to ga julọ nitori ẹrọ sisọ sisọ
  • Ipo ifarahan oju wiwo ati olubasọrọ iyasi latọna wa
  • Mono block type for single phase and three phase configuration are available

PCB iṣagbesori SPD – Pluggable nigba ti fi sori ẹrọ pẹlu soldering iho

The PCB mounting surge protective device is easy untegrated in PCB and close to sensitive electronic element inside device, to minimize the potential impact of lightning events. The PCB mounting SPD will help to significantly reduce the cost of substantial repair, replacement, system downtime and the loss of revenue.

Prosurge's PCB iṣagbesori SPD jẹ iṣapeye iwọn ati ṣiṣe aaye, eyiti o jẹ iṣẹ ṣiṣe giga ṣugbọn ojutu idiyele kekere fun ile-iṣẹ ti ẹrọ itanna agbara. O nlo agbara giga Metal Oxide Varistor (MOV), ati ti a ṣe pẹlu itọsi aabo igbona ati imọ-ẹrọ pipa arc eyiti o rii daju gige asopọ ailewu lakoko aṣiṣe lọwọlọwọ tabi foliteji ajeji ṣẹlẹ. Prosurge PCB iṣagbesori SPDs ti okeerẹ dara si awọn iṣẹ ailewu ati ki o fihan lati wa ni o tayọ kuna-ailewu ati awọn ẹrọ aabo ti ara-idaabobo nitori ti itọsi ọna ẹrọ.

  • Rating:
    • Fun AC ohun elo: Max. Tesiwaju iṣẹ foliteji (MCOV): 75 ~ 750Vac
    • Fun ohun elo DC/PV: Max. Agbara DC Foliteji (Vpvdc): 48-825Vdc
    • Agbara agbara (8/20 μs) :50kA ~ 80kA
    • Ilọju lọwọlọwọ (10/350 μs): 7.5kA ~ 12.5kA
    • SCCR(UL1449 5th):up to 200kA – tested without external CB or fuse
    • Iscpv (IEC61643-31):1000A
  • UL mọ Iru 1ca SPD (ANSI/UL1449 5th), Iru 2ca SPD (CSA-C22.2)
  • Ifọwọsi TUV gẹgẹbi boṣewa IEC 61643-31
  • Idahun ti awọn ọna kika kiakia ati iṣẹ-ṣiṣe ala-ẹrọ pipe ti o ni ibamu si pataki oniruuru asopọ-ẹrọ pẹlu ẹrọ apanirun arc
  • Iwọn otutu ibiti o ga julọ ati agbara to ga julọ
  • Ngbaradi agbara agbara lọwọlọwọ ati sisọ agbara kekere lọwọlọwọ
  • Lilọ ni ifipamo latọna jijin latọna jijin fun itọkasi aṣiṣe lakoko awọn afikun ipa ti PVD_Base

Awọn Ẹrọ Idaabobo Ẹtan Awọn Ọja Awọn Ẹjẹ Ìdílé

Tẹ lati ṣawari awọn ẹrọ aabo wa ti o gbooro sii ati awọn aabo awọn ina miiran.

Awọn Ọja Omiiran Alagbatọ ati Awọn Idaabobo Imọlẹ

Ijabọ Ọga

Surge Monitor

Imudara Equipotential Bonding

Awọn Ẹrọ Idaabobo Ẹtan Awọn Ọja Awọn Ẹjẹ Ìdílé

Tẹ lati ṣawari awọn ẹrọ aabo wa ti o gbooro sii ati awọn aabo awọn ina miiran.

Kan si Prosurge ati Gba Fesi ni Awọn wakati 2

wo bi ifigagbaga wa owo jẹ:)

Ìbásọsọ ifiweranṣẹ pẹlu wa nipa tite bọtini iwakọ ni igun ọtun isalẹ

Fọwọsi Fọọmu Kanti ati Gba idahun ni Awọn wakati 2





Fun ọja oja Ariwa Amerika, jowo kan si

+ 86 757 8632 7660

Fun awọn ọja miiran, jọwọ kan si

+ 86 757 8632 7660